HTV(Ningbo Bo Yue Elec) HT4100F-DC24V-SHG
| Manufacturer | HTV(Ningbo Bo Yue Elec)Asian Brands |
| MPN | HT4100F-DC24V-SHG |
| LCSC Part # | C126930 |
| Packaging | DIP,15.5x10.5mm |
| Customer # | |
| Key Attributes | RELAY POWER SPDT-CO 24V |
| Datasheet |
Products Specifications
Show similar products (0) >| Type | Description | |
|---|---|---|
| Category | Relays/Power Relays | |
| Manufacturer | HTV(Ningbo Bo Yue Elec) | |
| Packaging | DIP,15.5x10.5mm | |
| Contact Material | - | |
| Coil Type | Non-Polarized - Single Coil | |
| Coil Voltage | 24V | |
| Number of Pins | 6 | |
| Operating Temperature | -25℃~+75℃ | |
| Switching Current(Max) | - | |
| Release Time | 4ms | |
| Operate Time | 6ms | |
| Contact Resistance | 100mΩ | |
| Contact Rating | 3A@250VAC;3A@30VDC | |
| Length | 15.5mm | |
| Coil Rated Power | 360mW | |
| Switching Voltage(Max) | - | |
| Width | 10.5mm | |
| Contact Form | One set changeover: 1C (SPDT - changeover) | |
| Coil Resistance | - |
Report an ErrorShow similar products (0) >
Additional Information
| Type | Details |
|---|---|
| Minimum | 1 |
| Multiple | 1 |
| Standard Packaging | 25 |
| Sales Unit | Piece |
| EDA Models | EasyEDA Model |
Features
AI Translation
- Safety Standard: C-UL TUV
- Contact Gap: 0.18 mm minimum
- Contact Resistance: Initial max 100mΩ; test current 1A, open-circuit test voltage: 6VDC; measured by voltage drop method
- Contact Rating: 250VAC Cosφ = 1, 3A; 30VDC, 3A
- Rated Voltage: 3VDC, 5VDC, 6VDC, 9VDC, 12VDC, 24VDC
- Pick-up Voltage: (0.2W, 0.36W — the operate voltage as rated voltage is gradually applied to the coil is 75% of rated voltage; 0.15W is 80% of rated voltage)
- Drop-out Voltage: (the release voltage as rated voltage is gradually reduced is 10% of rated voltage)
- Maximum Allowable Voltage: (130% of rated voltage) V DC
- Operate Time: Max 6 milliseconds at rated voltage applied
- Release Time: Max 4 milliseconds at rated voltage suddenly removed
- Coil Temperature Rise: With maximum allowable voltage applied to the coil at no load, the temperature measured after stabilization shall not exceed 40℃ (ambient temperature excluded)
- Electrical Life: 3A/250VAC Cosφ = 1, min 100,000 operations at rated voltage; 3A/30VDC, min 100,000 operations at rated voltage
- Mechanical Life: Min 10,000,000 operations under no-load conditions
- Maximum Operating Frequency — Electrical: 30 operations/min; Mechanical: 300 operations/min
- Dielectric Strength: Between contacts: 500VAC, 50/60 Hz, leakage current < 1mA, for 1 minute; Between coil and contacts: 1,000VAC, 50/60 Hz, leakage current < 1mA, for 1 minute
- Insulation Resistance: ≧100 MΩ measured at 500VDC applied
- Vibration I (Endurance): Coil de-energized, double amplitude 1.5 mm, frequency swept from 10 to 55 Hz and back to 10 Hz within 1 minute, applied for 2 hours in each of three mutually perpendicular axes (6 hours total); no structural or visual deformation after test, and electrical specifications shall conform to requirements
- Vibration II (Functional): Coil energized, double amplitude 1.5 mm, frequency swept from 10 Hz to 55 Hz and back to 10 Hz within 1 minute, applied for 5 minutes in each X, Y, Z direction; no malfunction during test (contact discontinuity not to exceed 1 mS); no abnormality in appearance or structure after test, and electrical specifications shall conform to requirements
- Shock Resistance I (Endurance): Coil de-energized, acceleration 1000m/s², 5 shocks in each X, Y, Z direction; no abnormality in appearance or structure after test, and electrical specifications shall conform to requirements
- Shock Resistance II (Functional): Coil energized, acceleration 100m/s², 2 shocks in each X, Y, Z direction; no malfunction during test (contact discontinuity not to exceed 1 mS); no abnormality in appearance or structure after test, and electrical specifications shall conform to requirements
- Operating Temperature Range: -25 to +75°C; represents the temperature range within which the relay can operate continuously within the coil operate voltage range (no condensation at low temperature)
- Storage Temperature Range: The ambient temperature range within which the relay can be stored without damage (no condensation at low temperature)
Not available now
Products Specifications
Show similar products (0) >| Type | Description | |
|---|---|---|
| Category | Relays/Power Relays | |
| Manufacturer | HTV(Ningbo Bo Yue Elec) | |
| Packaging | DIP,15.5x10.5mm | |
| Contact Material | - | |
| Coil Type | Non-Polarized - Single Coil | |
| Coil Voltage | 24V | |
| Number of Pins | 6 | |
| Operating Temperature | -25℃~+75℃ | |
| Switching Current(Max) | - | |
| Release Time | 4ms | |
| Operate Time | 6ms | |
| Contact Resistance | 100mΩ | |
| Contact Rating | 3A@250VAC;3A@30VDC | |
| Length | 15.5mm | |
| Coil Rated Power | 360mW | |
| Switching Voltage(Max) | - | |
| Width | 10.5mm | |
| Contact Form | One set changeover: 1C (SPDT - changeover) | |
| Coil Resistance | - |
Report an ErrorShow similar products (0) >
Additional Information
| Type | Details |
|---|---|
| Minimum | 1 |
| Multiple | 1 |
| Standard Packaging | 25 |
| Sales Unit | Piece |
| EDA Models | EasyEDA Model |
Features
AI Translation
- Safety Standard: C-UL TUV
- Contact Gap: 0.18 mm minimum
- Contact Resistance: Initial max 100mΩ; test current 1A, open-circuit test voltage: 6VDC; measured by voltage drop method
- Contact Rating: 250VAC Cosφ = 1, 3A; 30VDC, 3A
- Rated Voltage: 3VDC, 5VDC, 6VDC, 9VDC, 12VDC, 24VDC
- Pick-up Voltage: (0.2W, 0.36W — the operate voltage as rated voltage is gradually applied to the coil is 75% of rated voltage; 0.15W is 80% of rated voltage)
- Drop-out Voltage: (the release voltage as rated voltage is gradually reduced is 10% of rated voltage)
- Maximum Allowable Voltage: (130% of rated voltage) V DC
- Operate Time: Max 6 milliseconds at rated voltage applied
- Release Time: Max 4 milliseconds at rated voltage suddenly removed
- Coil Temperature Rise: With maximum allowable voltage applied to the coil at no load, the temperature measured after stabilization shall not exceed 40℃ (ambient temperature excluded)
- Electrical Life: 3A/250VAC Cosφ = 1, min 100,000 operations at rated voltage; 3A/30VDC, min 100,000 operations at rated voltage
- Mechanical Life: Min 10,000,000 operations under no-load conditions
- Maximum Operating Frequency — Electrical: 30 operations/min; Mechanical: 300 operations/min
- Dielectric Strength: Between contacts: 500VAC, 50/60 Hz, leakage current < 1mA, for 1 minute; Between coil and contacts: 1,000VAC, 50/60 Hz, leakage current < 1mA, for 1 minute
- Insulation Resistance: ≧100 MΩ measured at 500VDC applied
- Vibration I (Endurance): Coil de-energized, double amplitude 1.5 mm, frequency swept from 10 to 55 Hz and back to 10 Hz within 1 minute, applied for 2 hours in each of three mutually perpendicular axes (6 hours total); no structural or visual deformation after test, and electrical specifications shall conform to requirements
- Vibration II (Functional): Coil energized, double amplitude 1.5 mm, frequency swept from 10 Hz to 55 Hz and back to 10 Hz within 1 minute, applied for 5 minutes in each X, Y, Z direction; no malfunction during test (contact discontinuity not to exceed 1 mS); no abnormality in appearance or structure after test, and electrical specifications shall conform to requirements
- Shock Resistance I (Endurance): Coil de-energized, acceleration 1000m/s², 5 shocks in each X, Y, Z direction; no abnormality in appearance or structure after test, and electrical specifications shall conform to requirements
- Shock Resistance II (Functional): Coil energized, acceleration 100m/s², 2 shocks in each X, Y, Z direction; no malfunction during test (contact discontinuity not to exceed 1 mS); no abnormality in appearance or structure after test, and electrical specifications shall conform to requirements
- Operating Temperature Range: -25 to +75°C; represents the temperature range within which the relay can operate continuously within the coil operate voltage range (no condensation at low temperature)
- Storage Temperature Range: The ambient temperature range within which the relay can be stored without damage (no condensation at low temperature)
Compliance & Export Codes
| Type | Details |
|---|---|
| RoHS | |
| ECCN | |
| CNHTS | 8536411090 |
| USHTS | 8536410030 |
| TARIC | 8536411090 |
| CAHTS | 8536410099 |
| BRHTS | 85364100 |
| INHTS | 85364100 |
| MXHTS | 8536.41.10 |
| Type | Details |
|---|---|
| RoHS | |
| ECCN | |
| CNHTS | 8536411090 |
| USHTS | 8536410030 |
| TARIC | 8536411090 |
| Type | Details |
|---|---|
| CAHTS | 8536410099 |
| BRHTS | 85364100 |
| INHTS | 85364100 |
| MXHTS | 8536.41.10 |