Images
|
Pricing
|
Quantity
|
Availability
|
Mfr.Part #
|
Manufacturer
|
Description
|
RoHS
|
LCSC Part#
|
Package
|
Packaging
|
Insulation Resistance Test Range
|
Frequency Measurement Range
|
Display Type
|
Voltage Test Range
|
Resistance Test Range
|
Ground Resistance Test Range
|
Operating Mode
|
Type
|
Leakage Current Test Range
|
DC Current Test Range
|
DC Output Voltage Range
|
Testable Parameters
|
AC Output Voltage Range
|
Test Mode
|
AC Current Test Range
|
---|
Images
|
Pricing
|
Quantity
|
Availability
|
Mfr.Part #
|
Manufacturer
|
Description
|
RoHS
|
LCSC Part#
|
Package
|
Packaging
|
Insulation Resistance Test Range
|
Frequency Measurement Range
|
Display Type
|
Voltage Test Range
|
Resistance Test Range
|
Ground Resistance Test Range
|
Operating Mode
|
Type
|
Leakage Current Test Range
|
DC Current Test Range
|
DC Output Voltage Range
|
Testable Parameters
|
AC Output Voltage Range
|
Test Mode
|
AC Current Test Range
|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Min: 1 Mult: 1 | 0 | MS2675PN-IIA | Minshen | Safety Test Instrument | - | C22447178 | - | Box-packed | - | - | Digital | AC 0kV~5kV DC 0kV~6kV | 1-10000MΩ | - | Manual | Insulation withstand voltage | - | 0-5mA | - | Insulation resistance/Withstand voltage | - | - | 0-12mA | |
| Min: 1 Mult: 1 | 0 | MS2675PN-IB | Minshen | Safety Test Instrument | - | C22447320 | - | Box-packed | - | - | Digital | AC 0kV~5kV | 1-10000MΩ | - | Manual | Insulation withstand voltage | - | - | - | Insulation resistance/Withstand voltage | - | - | 0-20mA | |
| Min: 1 Mult: 1 | 0 | MS2621PN | Minshen | Safety Test Instrument | - | C22447322 | - | Box-packed | - | - | Digital | AC 80V~250V | - | - | Manual | Leakage current | 0.1-99.9μA/100-999.9μA/1000-9999μA | - | - | Leakage current | - | Automatic Test Mode | - | |
| Min: 1 Mult: 1 | 0 | MS2671PN-IIA | Minshen | Safety Test Instrument | - | C22447323 | - | Box-packed | - | - | Digital | AC 0kV~10kV DC 0kV~10kV | - | - | Manual | All-in-one | - | 0-5mA | - | Leakage Current/Withstand Voltage | - | - | 0-10mA | |
| Min: 1 Mult: 1 | 0 | MS2621GN-IB | Minshen | Safety Test Instrument | - | C22447324 | - | Box-packed | - | - | Digital | - | - | - | Manual | Leakage current | 100-999.9μA/1000-9999μA/3-99.9μA | - | - | Leakage current | - | Automatic Test Mode | - | |
| Min: 1 Mult: 1 | 0 | MS2621H-IA | Minshen | Safety Test Instrument | - | C22447332 | - | Box-packed | - | - | Digital | - | - | - | Manual | Leakage current | 0-10000μA | - | - | Leakage current | 200V-450V | - | - | |
| Min: 1 Mult: 1 | 0 | MS2621B | Minshen | Safety Test Instrument | - | C22447333 | - | Box-packed | - | - | Digital | - | - | - | Manual | Leakage current | 0.2mA-20mA | - | - | Leakage current | - | - | - | |
| Min: 1 Mult: 1 | 0 | MS2621A | Minshen | Safety Test Instrument | - | C22447334 | - | Box-packed | - | - | Digital | - | - | - | Manual | Leakage current | 0.2mA-20mA | - | - | Leakage current | - | - | - | |
| Min: 1 Mult: 1 | 0 | MS2621N | Minshen | Safety Test Instrument | - | C22447335 | - | Box-packed | - | - | Digital | - | - | - | Manual | Leakage current | 0.2mA-20mA | - | - | Leakage current | - | - | - | |
| Min: 1 Mult: 1 | 0 | MS2520AN | Minshen | Safety Test Instrument | - | C22447338 | - | Box-packed | - | - | Digital | 12V | - | 0MΩ-200MΩ/0MΩ-500MΩ/0MΩ-600MΩ | Manual | Ground resistance | - | - | - | Ground resistance | - | - | - | |
| Min: 1 Mult: 1 | 0 | MS2671AN | Minshen | Safety Test Instrument | - | C22447341 | - | Box-packed | - | - | Digital | AC 0kV~10kV DC 0kV~10kV | - | - | Manual | All-in-one | 0-10mA/0-20mA | - | - | Leakage Current/Withstand Voltage | - | - | - | |
| Min: 1 Mult: 1 | 0 | MS2670BN | Minshen | Safety Test Instrument | - | C22447343 | - | Box-packed | - | - | Digital | AC 0kV~5kV DC 0kV~5kV | - | - | Manual | All-in-one | 0-10mA/0-20mA | - | - | Leakage Current/Withstand Voltage | - | - | - | |
| Min: 1 Mult: 1 | 0 | TH2686N | Tonghui | Safety Test Instrument | - | C34373806 | - | - | - | - | Digital | - | - | - | Manual | Leakage current | 10nA-19.99mA | - | - | Leakage current | - | - | - | |
| Min: 1 Mult: 1 | 0 | TH9410A | Tonghui | Safety Test Instrument | - | C34373846 | - | - | - | - | Digital | - | - | 0MΩ-600MΩ | Manual | Ground resistance | - | - | - | Ground resistance | - | 4-wire method | - | |
| Min: 1 Mult: 1 | 0 | TH9411A | Tonghui | Safety Test Instrument | - | C34373849 | - | - | - | - | Digital | - | - | 0MΩ-600MΩ | Manual | Ground resistance | - | - | - | Ground resistance | - | 4-wire method | - | |
| Min: 1 Mult: 1 | 0 | 99-4040-515 | baty | Safety Test Instrument | - | C7445901 | - | - | - | - | Digital | - | - | 0.01Ω-0.099Ω/0.1Ω-0.99Ω/100Ω-199Ω/1Ω-49.9Ω/200Ω-395Ω/400Ω-590Ω/50Ω-99.5Ω/600Ω-880Ω/900Ω-1200Ω | Portable | Ground resistance | - | - | - | Loop resistance/ground resistance | - | - | - | |
| Min: 1 Mult: 1 | 0 | 99-4040-518 | baty | Safety Test Instrument | - | C7445902 | - | - | - | - | Digital | - | - | 0.01Ω-20Ω/0.1Ω-200Ω/1Ω-2000Ω | Online | Ground resistance | - | - | - | Ground resistance | - | - | - | |
| Min: 1 Mult: 1 | 0 | 99-4040-520 | baty | Safety Test Instrument | - | C7445904 | - | - | - | - | Digital | - | - | 0.01Ω-2kΩ | Manual | Ground resistance | - | - | - | Ground resistance | - | 2-wire method/3-wire method | - | |
| Min: 1 Mult: 1 | 0 | 99-4040-521 | baty | Safety Test Instrument | - | C7445905 | - | - | - | - | Digital | - | - | 0Ω-30kΩ | Manual | Ground resistance | - | - | - | Ground resistance | - | 2-wire method / 3-wire method / 4-wire method | - | |
| Min: 1 Mult: 1 | 0 | VICTOR 4106C | VICTOR(Double King Industrial Holdings) | Safety Test Instrument | - | C7463799 | - | - | - | - | Digital | - | - | 0MΩ-200kΩ | Manual | Ground resistance | - | - | - | Ground resistance | - | - | - | |
| Min: 1 Mult: 1 | 0 | VICTOR 6410 | VICTOR(Double King Industrial Holdings) | Safety Test Instrument | - | C7463800 | - | - | - | - | Digital | - | - | 0.01Ω-200Ω | Portable | Ground resistance | - | - | - | Ground resistance | - | - | - | |
| Min: 1 Mult: 1 | 0 | VICTOR 6412 | VICTOR(Double King Industrial Holdings) | Safety Test Instrument | - | C7463802 | - | - | - | - | Digital | - | - | 0.01Ω-1300Ω | Portable | Ground resistance | - | - | - | Ground resistance | - | - | - | |
| Min: 1 Mult: 1 | 0 | VICTOR 6418B | VICTOR(Double King Industrial Holdings) | Safety Test Instrument | - | C7463809 | - | - | - | - | Pointer type | - | - | 0.01Ω-100Ω/0.01Ω-200Ω | Online | Ground resistance | - | - | - | Loop resistance/ground resistance | - | - | - | |
| Min: 1 Mult: 1 | 0 | GE70-400-2261 | UTICA | Safety Test Instrument | - | C7449246 | - | Bag-packed | - | - | Digital | 380V | - | - | Portable | Leak switch | 0-500mA | - | - | Action Time/Leakage Current/Withstand Voltage | - | - | - | |
| Min: 1 Mult: 1 | 0 | 61360992 | EDMUND BUHLERGMBH | Safety Test Instrument | - | C7449661 | - | - | - | - | Digital | - | 1μΩ-20kΩ | - | Manual | Contact resistance | - | - | - | Contact resistance | - | 4-wire method/manual test mode/automatic test mode | - |